Introducing the state-of-the-art HLPSL and HLPSV load-sensitive proportional multi-way directional spool valves. These engineering marvels seamlessly integrate pressure, flow, and direction control into one cohesive unit. Typically, they consist of three essential functional modules: connecting blocks, directional valves, and end plates. Designed for hydraulic systems in engineering machinery, they expertly manage the movement direction and speed of hydraulic cylinders, motors, and other actuators. Notable features include a compact structure, exceptional energy efficiency, and the capability for stepless speed control. Additionally, they enable multiple actuators to operate in unison under varying loads, ensuring unparalleled performance and versatility.
The HLPSL valves are tailored for constant displacement pump systems, whereas the HLPSV valves are engineered for variable pump systems. Although HLPSV valves may exhibit a slightly slower response time, they excel in delivering superior energy-saving performance, making them the optimal choice for applications where efficiency is paramount.
References |
size 2 |
size 3 |
size 5 |
Number of Directional Valve bank |
1~12 |
1~12 |
1~10 |
Port access type |
thread connection |
thread connection |
thread connection |
Flow code |
3,6,10,16,25,40 |
3,6,10,16,25,40,63,80 |
16,25,40,63,80,120,160 |
Max.flow(L/min) |
54 |
100 |
210 |
Max.pressure(bar) |
420 |
420 |
420 |
Control Method |
Pilot circuit pressure(bar) |
20~40 |
20~40 |
20~40 |
Manual force(N) |
≥2.3Nm |
≥1.3Nm |
≥3Nm |
Working Pressure(ºC) |
-40~80 |
-40~80 |
-40~80 |
Weight |
Connection Block (kg) |
1.7 |
4 |
8 |
Directional Valve bank (kg) |
1.9 |
4 |
8 |
End Plate (kg) |
0.5 |
1.5 |
2.5 |
Fix mode |
thread connection M8 |
thread connection M8 |
thread connection M10 |
Installation Instructions
(1)Basic code of connection block
HLPSL: for constant displacement pump applications;
HLPSV: for variable displacement pump applications;
(2) Port P & R of the connection block:
2-G3/8;
3-G1/2;
4-G3/4;
5, 55-G1;
6-G1 1/4;
(3)Additional components:
C,standard type;
G,throttle valve (exclusive for HLPSL);
H,fixed differential overflow valve to enhance circulating pressure (approx. 14 bar, HLPSL);
(4)Pilot oil circuit pressure:0 - without pressure reducing valve; 1 - with pressure reducing valve (20 bar); 2 - with pressure reducing valve (40 bar);
(5)2/2-way magnetic ball valve for system unloading: C - without magnetic ball valve; F - normally open magnetic ball valve (pressurizes pump when powered, unloads when power fails); D - normally closed magnetic ball valve (unloads pump when powered, pressurizes when power fails);./F, with pressure limiting valve, can serve as secondary pressure (F50) with indicated pressure value;
(6)Tool adjustable, pressure limiting valve in the connection block: Pressure limiting valve settings such as 63, 120, 210, 280, 315, 350, 400 bar; /NF: without pressure limiting valve (only for HLPSV);
(7)Product series: -2 series;-3 3 series; -5 5 series;
(8)Thread size of directional spool valve ports A & B: 2-G3/8; 3-G1/2; 4-G3/4; 5-G1; A, ancillary block or intermediate transition block ZPL 5S(V)/H hydraulic control shut-off valve;
(9)Directional valve block inflow controller: 1, without inflow controller; 2, standard inflow controller; 4, 3-way flow controllers for inlet and outlet (ideal for N 3/3-way valve); 5, strengthened inflow controller; 8, pre-selectable;
(10) Function symbol of valve core: L, M, F, H, J, B, R, O, N;
(11) Output flow code of ports A & B: Maximum output flow of ports A & B (typically select 3, 6, 10, 16, 25, 40, 63, 80, 120, 160, 210 (L/min);
(12) Secondary pressure limitation: N, no pressure limiting protection; C, limit the pressure of actuator ports A & B simultaneously; A---B---, limit the pressure of actuator ports A & B separately, unit (bar);
(13) Function ON/OFF and pressure outlet: N, without function ON/OFF and pressure outlet; X C type pressure limitation; S/S1 AB type pressure limitation; A, electrical ON/OFF on side A; B, electrical ON/OFF on side B;
(14) Operation manner: A(1,2), manual operation with long handle (1=without handle, 2=with short handle); E, electric proportional control; EA(1,2), electric proportional control and manual operation (1=without handle, 2=with short handle); D, electric switching value control; DA(1,2), electric switching value control and manual operation (1=without handle, 2=with short handle); M, manual friction positioning with long handle; H, pure hydraulic control (two pilot oil ports align with oil ports A and B); F, pure hydraulic control (two pilot oil ports are perpendicular to oil ports A and B and outward respectively);
(15) Ancillary block: /2 Ancillary block port size G3/8; /3 Ancillary block port size G1/2; /4 Ancillary block port size G3/4; /5 Ancillary block port size G1;
(16) End plate: E1, standard end plate, external discharge of pilot oil, connecting oil return control port T externally; E2, similar to E1, external discharge of pilot oil, port Y is additionally attached; E3, external discharge of pilot oil, a 2-position 3-way magnetic ball valve is mounted; in power supply scenarios, the system pressure rises to the safety valve pressure;
E4, similar to E1, internal discharge of pilot oil, port T can be sealed; E5, similar to E2, internal discharge of pilot oil, port T can be sealed; E6, similar to E3, internal discharge of pilot oil, port T can be sealed;
(17) Control voltage and the length of anti-explosion type cable: G12-12VDC;G24-24VDC; G24Ex-3m-24VDC; G12Ex-3m-12VDC; G24MA-3m-24VDC; G128d8c00df
Since our inception in 2009, Jiangsu KM Hydraulic Control System Co., Ltd. has illuminated the hydraulic industry with unparalleled innovation and excellence. As a proud member of the China Baoan Group (stock code: 000009) and a distinguished national high-tech enterprise, we stand at the forefront of hydraulic component research, development, manufacturing, and sales. Our prestigious designation as a national 'specialized, refined, and innovative' small giant enterprise underscores our unwavering commitment to technological prowess and superior quality.
Our flagship product, the Load Sensitive Valve with Hawe Type PSL and PSV Proportional Valve Distributor, defines the pinnacle of advanced hydraulic system control. Meticulously engineered for construction machinery and heavy-duty equipment, this versatile component is essential in emergency rescue operations, tunnel engineering, mining applications, and municipal service vehicles. We are honored to partner with numerous leading domestic manufacturers, playing a pivotal role in the localization of core hydraulic components for high-end mechanical equipment. Embracing our core philosophy of 'serving customers with technology, impressing customers with our attitude, and retaining customers with quality,' we are steadfast in our mission to deliver exceptional products, services, and solutions. Our vision is to establish ourselves as a globally trusted supplier of premier hydraulic components.
Customer Inquiry1. What about the lead time?
Response:Our standard lead time for production is approximately one month following the receipt of payment.
Customer Inquiry2. Do you have any MOQ limit for LED light orders?
Response: We have a very low minimum order quantity; you can even order a single piece for sample evaluation.
Customer Inquiry3. How to proceed with an order for LED lights?
Response: To initiate an order, please follow these steps: First, communicate your specific requirements or the intended application. Second, we will deliver a tailored quote based on your needs or our professional recommendations. Third, confirm thedrawings and place a deposit to formalize the order. Finally, we will commence the production process.
Customer Inquiry4. Is it OK to print my logo on the product?
Response: Absolutely. Please inform us officially before production begins and approve the design based on the sample we provide.