Introducing the state-of-the-art HLPSL and HLPSV load-sensitive proportional multi-way directional spool valves. These engineering marvels seamlessly integrate pressure, flow, and direction control into one cohesive unit. Typically, they consist of three essential functional modules: connecting blocks, directional valves, and end plates. Designed for hydraulic systems in engineering machinery, they expertly manage the movement direction and speed of hydraulic cylinders, motors, and other actuators. Notable features include a compact structure, exceptional energy efficiency, and the capability for stepless speed control. Additionally, they enable multiple actuators to operate in unison under varying loads, ensuring unparalleled performance and versatility.
The HLPSL valves are tailored for constant displacement pump systems, whereas the HLPSV valves are engineered for variable pump systems. Although HLPSV valves may exhibit a slightly slower response time, they excel in delivering superior energy-saving performance, making them the optimal choice for applications where efficiency is paramount.
References |
size 2 |
size 3 |
size 5 |
Number of Directional Valve bank |
1~12 |
1~12 |
1~10 |
Port access type |
thread connection |
thread connection |
thread connection |
Flow code |
3,6,10,16,25,40 |
3,6,10,16,25,40,63,80 |
16,25,40,63,80,120,160 |
Max.flow(L/min) |
54 |
100 |
210 |
Max.pressure(bar) |
420 |
420 |
420 |
Control Method |
Pilot circuit pressure(bar) |
20~40 |
20~40 |
20~40 |
Manual force(N) |
≥2.3Nm |
≥1.3Nm |
≥3Nm |
Working Pressure(ºC) |
-40~80 |
-40~80 |
-40~80 |
Weight |
Connection Block (kg) |
1.7 |
4 |
8 |
Directional Valve bank (kg) |
1.9 |
4 |
8 |
End Plate (kg) |
0.5 |
1.5 |
2.5 |
Fix mode |
thread connection M8 |
thread connection M8 |
thread connection M10 |
Installation Instructions
(1)Basic Code of Connection Block
HLPSL: Constant Displacement Pump;
HLPSV: Variable Displacement Pump;
(2) Port P & R of the Connection Block:
2-G3/8;
3-G1/2;
4-G3/4;
5, 55-G1;
6-G1 1/4;
(3)Additional Component:
C,Standard Type;
G,Throttle Valve (only used for HLPSL);
H,Fixed Differential Overflow Valve for Improving the Circulating Pressure (about 14 bar, HLPSL);
(4)Pilot Oil Circuit Pressure:0 Without Pressure Reducing Valve; 1 With Pressure Reducing Valve (20 bar); 2 With Pressure Reducing Valve (40 bar);
(5)2/2-Way Magnetic Ball Valve for System Unloading: C, Without Magnetic Ball Valve; F, Normally Open Magnetic Ball Valve, in Case of Power Supply, the Pump is Pressurized; in Case of Power Failure, the Pump Carries Out Unloading; D: Normally Closed Magnetic Ball Valve, in Case of Power Supply, the Pump Carries Out Unloading; in Case of Power Failure, the Pump is Pressurized; D../F. . , With Pressure Limiting Valve, it Can Serve as Secondary Pressure (F50) with Pressure Value Indicated;
(6)Tool Adjustable, Pressure Limiting Valve in the Connection Block: Pressure Limiting Valve Sets such as 63, 120, 210, 280, 315, 350, 400 bar; /NF: Without Pressure Limiting Valve (only for HLPSV);
(7)Product Series: -2 Series;-3 3 Series; -5 5 Series;
(8)Thread size for directional spool valve ports A & B: 2-G3/8; 3-G1/2; 4-G3/4; 5-G1. Ancillary block or intermediate transition block ZPL 5S(V)/H hydraulic control shut-off valve;
(9)Directional valve block inflow controller options: 1. No inflow controller; 2. Standard inflow controller; 4. 3-way flow controllers for both inlet and outlet (ideal for N 3/3-way valve); 5. Strengthened inflow controller; 8. Pre-selectable;
(10) Valve core function symbols: L, M, F, H, J, B, R, O, N;
(11) Output flow code for ports A & B: Maximum output flow (typically selected as 3, 6, 10, 16, 25, 40, 63, 80, 120, 160, 210 L/min);
(12) Secondary pressure limitation: N, no pressure limiting protection; C, limit the pressure of actuator ports A & B simultaneously; A---B---, limit the pressure of actuator ports A & B separately (unit: bar);
(13) Function ON/OFF and pressure outlet: N, without function ON/OFF and pressure outlet; X, C type pressure limitation; S/S1, AB type pressure limitation; A, electrical ON/OFF on side A; B, electrical ON/OFF on side B;
(14) Operation manner: A(1,2), manual operation with long handle (1=without handle, 2=with short handle); E, electric proportional control; EA(1,2), electric proportional control and manual operation (1=without handle, 2=with short handle); D, electric switching value control; DA(1,2), electric switching value control and manual operation (1=without handle, 2=with short handle); M, manual friction positioning with long handle; H, pure hydraulic control (two pilot oil ports align with oil ports A and B); F, pure hydraulic control (two pilot oil ports are perpendicular to oil ports A and B and outward respectively);
(15) Ancillary block: /2 Ancillary block port size G3/8; /3 Ancillary block port size G1/2; /4 Ancillary block port size G3/4; /5 Ancillary block port size G1;
(16) End plate options: E1, standard end plate with external discharge of pilot oil and external connection of oil return control port T; E2, similar to E1, with additional port Y; E3, with external discharge of pilot oil and a 2-position 3-way magnetic ball valve, system pressure rises to safety valve pressure under power supply scenario;
E4, similar to E1 with internal discharge of pilot oil, port T can be sealed; E5, similar to E2 with internal discharge of pilot oil, port T can be sealed; E6, similar to E3 with internal discharge of pilot oil, port T can be sealed;
(17) Control voltage and anti-explosion cable length: G12-12VDC;G24-24VDC; G24Ex-3m-24VDC; G12Ex-3m-12VDC; G24MA-3m-24VDC; G12MA-3m-12VDC (anti-explosion type, guide line lengths: 3m, 5m, 10m, etc.)
Since our inception in 2009, Jiangsu KM Hydraulic Control System Co., Ltd. has stood as a beacon of innovation and excellence in the hydraulic industry. As an esteemed member of the China Baoan Group (stock code: 000009) and honored as a national high-tech enterprise, we excel in the research, development, manufacturing, and sales of superior hydraulic components. Our recognition extends to being designated as a national 'specialized, refined, and innovative' small giant enterprise, underlining our unwavering commitment to technological advancement and quality.
Our flagship product, the load-sensitive proportional valve, epitomizes cutting-edge hydraulic system control. Specifically engineered for construction machinery and heavy-duty equipment, this adaptable component is indispensable in emergency rescue operations, tunnel engineering, mining applications, and municipal service vehicles. We proudly collaborate with numerous prominent domestic manufacturers, significantly contributing to the localization of core hydraulic components for high-end mechanical equipment. Guided by our core philosophy of 'serving customers with technology, impressing customers with our attitude, and retaining customers with quality,' we are unwavering in our dedication to delivering exceptional products, services, and solutions. Our mission is to become a globally trusted supplier of premier hydraulic components.
Customer Inquiries1. What about the lead time?
Response:The lead time for production is typically one month after payment has been received.
Customer Inquiries2. Do you have any MOQ limit for LED light orders?
Response: We offer a remarkably low minimum order quantity; even a single piece for sample checking is available.
Customer Inquiries3. How to proceed with an order for LED lights?
Response: First, let us know your specific requirements or application. Second, we will provide a comprehensive quote based on your needs or our expert recommendations. Third, you confirm thedrawings and place a deposit to formalize the order. Finally, we will arrange the production with precision.
Customer Inquiries4. Is it OK to print my logo on the product?
Response: Absolutely, it is possible. Please inform us formally before production starts and confirm the design based on the sample we provide.